Electrical Power Transformer | Definition and Types of Transformer

Electrical Power Transformer | Definition and Types of Transformer

Definition of Transformer

A transformer is a static machine used for transforming power from one circuit to another without changing frequency. This is a very basic definition of transformer.

History of Transformer

The history of transformer was commenced in the year 1880. In the year 1950, 400KV electrical power transformer was introduced in high voltageelectrical power system. In the early 1970s, unit rating as large as 1100MVA was produced and 800KV and even higher KV class transformers were manufactured in year of 1980.

Use of Power Transformer

Generation of electrical power in low voltage level is very much cost effective. Hence electrical power is generated in low voltage level. Theoretically, this low voltage level power can be transmitted to the receiving end. But if the voltage level of a power is increased, the current of the power is reduced which causes reduction in ohmic or I2R losses in the system, reduction in cross sectional area of the conductor i.e. reduction in capital cost of the system and it also improves the voltage regulation of the system. Because of these, low level power must be stepped up for efficientelectrical power transmission. This is done by step up transformer at the sending side of the power system network. As this high voltage power may not be distributed to the consumers directly, this must be stepped down to the desired level at the receiving end with the help of step down transformer. These are the uses of electrical power transformer in theelectrical power system.
power transformer
Two winding transformers are generally used where ratio between high voltageand low voltage is greater than 2. It is cost effective to use auto transformer where the ratio between highvoltage and low voltage is less than 2. Again three phase single unit transformer is more cost effective than a bank of three single phase transformer unit in a three phase system. But still it is preferable to use than the later where power dealing is very large since such large size of three phase single unit power transformer may not be easily transported from manufacturer’s place to work site.

Types of Transformer

Transformers can be categorized in different ways, depending upon their purpose, use, construction etc. The types of transformer are as follows,
  1. Step Up Transformer & Step Down Transformer – Generally used for stepping up and down the voltage level of power in transmission and distribution power network.
  2. Three Phase Transformer & Single Phase Transformer – Former is generally used in three phase power system as it is cost effective than later but when size matters, it is preferable to use bank of three single phase transformer as it is easier to transport three single phase unit separately than one single three phase unit.
  3. electrical power transformer
  4. Electrical Power Transformer, Distribution Transformer & Instrument Transformer - Transformer is generally used in transmission network which is normally known as power transformer, distribution transformer is used in distribution network and this is lower rating transformer and current transformer & potential transformer, we use for relay and protection purpose in electrical power system and in different instruments in industries are called instrument transformer.
  5. Two Winding Transformer & Auto Transformer – Former is generally used where ratio between high voltage and low voltage is greater than 2. It is cost effective to use later where the ratio between high voltage and low voltage is less than 2.
  6. Outdoor Transformer & Indoor Transformer – Transformers that are designed for installing at outdoor are outdoor transformers and transformers designed for installing at indoor are indoor transformers.

Introduction of Transformer

Types of Transformer Transformers can be categorized in different ways, depending upon their purpose, use, construction etc. The types of transformer are as follows, Step Up Transformer & Step Down Transformer – Generally used for stepping up and down the voltage level of power in transmission and distribution power network. Three Phase Transformer & Single Phase Transformer – Former is generally used in three phase power system as it is cost effective than later but when size matters, it is preferable to use bank of three single phase transformer as it is easier to transport three single phase unit separately than one single three phase unit. electrical power transformer Electrical Power Transformer, Distribution Transformer & Instrument Transformer - Transformer is generally used in transmission network which is normally known as power transformer, distribution transformer is used in distribution network and this is lower rating transformer and current transformer & potential transformer, we use for relay and protection purpose in electrical power system and in different instruments in industries are called instrument transformer. Two Winding Transformer & Auto Transformer – Former is generally used where ratio between high voltage and low voltage is greater than 2. It is cost effective to use later where the ratio between high voltage and low voltage is less than 2. Outdoor Transformer & Indoor Transformer – Transformers that are designed for installing at outdoor are outdoor transformers and transformers designed for installing at indoor are indoor transformers. Introduction of Transformer

Induction Motor | Working Principle | Types of Induction Motor


One of the most common electrical motor used in most applications which is known as induction motor. This motor is also called as asynchronous motor because it runs at a speed less than synchronous speed. In this, we need to define what is synchronous speed. Synchronous speed is the speed of rotation of the magnetic field in a rotary machine and it depends upon the frequency and number poles of the machine. An induction motoralways runs at a speed less than synchronous speed because the rotatingmagnetic field which is produced in the stator will generate flux in the rotor which will make the rotor to rotate, but due to the lagging of flux current in the rotor with flux current in the stator, the rotor will never reach to its rotating magnetic field speed i.e. the synchronous speed. There are basically two types of induction motor that depend upon the input supply – single phase induction motor and three phase induction motorSingle phase induction motor is not a self starting motor which we will discuss later and three phase induction motor is a self-starting motor. Now in general we need to give two supply i.e. double excitation to make a machine to rotate. For example if we consider a DC motor, we will give one supply to the stator and another to the rotor through brush arrangement.

Working Principle of Induction Motor

But in induction motor we give only one supply, so it is really interesting to know that how it works. It is very simple, from the name itself we can understand that there is induction process occurred. Actually when we are giving the supply to the stator winding, flux will generate in the coil due to flow of current in the coil. Now the rotor winding is arranged in such a way that it becomes short circuited in the rotor itself. The flux from the stator will cut the coil in the rotor and since the rotor coils are short circuited, according to Faraday’s law of electromagnetic inductioncurrent will start flowing in the coil of the rotor. When the current will flow, another flux will get generated in the rotor. Now there will be two flux, one is stator flux and another is rotor flux and the rotor flux will be lagging to the stator flux. Due to this, the rotor will feel a torque which will make the rotor to rotate in the direction of rotating magnetic flux. So the speed of the rotor will be depending upon the ac supply and the speed can be controlled by varying the input supply. This is the working principle of an induction motor of either type.

Types Induction Motor

    SINGLE PHASE INDUCTION MOTOR
    1. Split phase induction motor
    2. Capacitor start induction motor
    3. Capacitor start capacitor run induction motor
    4. Shaded pole induction motor
      THREE PHASE INDUCTION MOTOR
      1. Squirrel cage induction motor
      2. Slip ring induction motor
      We had mentioned above that single phase induction motor is not a self starting and three phase induction motor is self starting. So what is self starting? When the machine starts running automatically without any external force to the machine, then it is called as self starting. For example we see that when we press the key the fan starts to rotate automatically, so it is self starting. Point to be note that fan used in home appliances is single phase induction motor but it is self starting. How? We will discuss it how.

      Why is Three Phase Induction Motor Self Starting?

      In three phase system, there are three single phase line with 120° phase difference. So the rotating magnetic field is having the same phase difference which will make the rotor to move. If we consider three phases a, b and c, when phase a is magnetized, the rotor will move towards the phase a winding, in the next moment phase b will get magnetized and it will attract the rotor and than phase c. So the rotor will continue to rotate.

      Why Single Phase Induction Motor is not Self Starting?

      But what about single phase. It will be having only one phase still it makes the rotor to rotate, so it is quite interesting. Before that we need to know why single phase induction motor is not a self starting motor and how the problem is overcome. We know that the ac supply is a sinusoidal wave and it produces pulsatingmagnetic field in uniformly distributed stator winding. Since pulsating magnetic field can be assumed as two oppositely rotating magnetic fields, there will be no resultant torque produced at the starting and due to this the motor does not run. After giving the supply, if the rotor is made to rotate in either direction by external force, then the motor will start to run. This problem has been solved by making the stator winding into two winding, one is main winding and another is auxiliary winding and a capacitor is fixed in series with the auxiliary winding. This will make a phase difference when current will flow through the both coils. When there will be phase difference, the rotor will generate a starting torque and it will start to rotate. Practically we can see that the fan does not rotate when the capacitor is disconnected from the motor but if we rotate with hand it will start to rotate. So this is the reason of using capacitor in thesingle phase induction motor. There are several advantages ofinduction motor which makes this motor to have wider application. It is having good efficiency up to 97%. But the speed of the motor varies with the load given to the motor which is an disadvantage of this motor. The direction of rotation ofinduction motor can easily be changed by changing the sequence of three phase supply, i.e. if RYB is in forward direction, the RBY will make the motor to rotate in reverse direction. This is in the case of three phase motor but in single phase motor, the direction can be reversed by reversing thecapacitor terminals in the winding.